CH4656: Network alarm and battery control

SAILOR CH4656 in a photo from OmegaCharge's own catalogue. External control devices, batteries and cables are not identified from this photo.
Request SAILOR CH4656When buying a CH4656 for an existing installation, it is important to keep not only the battery charge, but also the condition signals provided. The presence of the output voltage does not yet indicate whether the watch will know about the disappearance of the main network. Therefore, the charger and control circuits are agreed as parts of the same circuit.
Two control outputs solve different tasks
CH4656/CH4666/CH2410 lists AC Mains Alarm output and Battery-protected monitoring output for the CH4656. The first is a power supply accident, the second is a battery control accident. These designations cannot be combined into an arbitrary “digital interface” or automatically considered a ready-made alert system.
For AC Mains Alarm, the technical data indicate the emergency closed relay contacts and the ranges of 5–50 mA, 10–32 V. These are signal chain parameters, not an additional power output for power supply devices. The method of connection and the admissibility of the existing chain are checked by documentation of both parties.
Indicate who is receiving the signal.
The application requires not only a charger, but also the name of the connected panel, control unit or other receiving equipment. Attach a diagram, terminal markings and known entry parameters. If the previous scheme is missing, please let us know: the purchase of the new CH4656 does not confirm the compatibility of the unknown line.
To control the battery separately specify the purpose of the existing external device and the applicable connection scheme. The title of the protected output does not promise any alarm threshold, built-in remote indicator or record all events. These functions should be explicitly provided by the composition of your system.
What to include in one order statement
The basic position is CH4656 in consistent configuration and condition. Next, the stored batteries, external control devices, cables and accessories that will need to be supplied additionally are recorded. If you need a new panel or other intermediate node, it is first selected by task and documentation, then included in the quotation. A random panel by the common word “alarm” is not substituted.
The cost of the existing card relates to the specified charger. It does not mean that it is automatically attached to an external panel, new batteries, all the cable installation and configuration of the marine system. The result of the agreed package is recorded in the quotation; the related products below are shown separately.
How to describe the reception without guessing
Before installation, agree on what event the operator should receive, on which device it is displayed and how the restoration of normal state is confirmed. The efficiency of the own display of the charger and the work of the remote panel are different checkpoints. In the acceptance program, they must remain distinguishable.
The control change in the state of power supply is carried out by specialists in documentation and approved scheme, taking into account the existing equipment. There is no universal procedure for disabling the operating system. The result should be a clear record of the circuits tested, the settings applied, and the limitations stored, not just the “charged on” mark.
What to send for purchase
Indicate the marking of the former CH4656, battery data, main network parameters, the model of the receiving panel and a list of stored connections. Add the number of devices and the city of receipt – for example, St. Petersburg, Murmansk or Vladivostok. We will agree on delivery and completeness; term, documents and delivery will be confirmed in the quotation.
- CH4656: intended control outputs
- Harmonized signal chains
- External device and indication
A simplified scheme for agreeing delivery. It does not replace the working connection scheme.
| Part of the system | What's the deal? |
|---|---|
| AC Mains Alarm | Definition of input of receiving device and signal chain |
| Battery monitoring | External control device and applicable circuitry |
| Delivery | Configuration CH4656, accessories and retained parts |
| Acceptance | Displaying events, restoring state and recording the result |
Questions before ordering
Can the AC Mains Alarm signal power other equipment?
The manual for it indicates the signal contacts of the relay. It is not considered as an additional power source; the parameters of the circuit are checked with the documentation of the charger and the receiving device.
Is the remote panel included in the CH4656 price?
The composition is determined by quotation. The presence of control outputs in itself does not mean the supply of an external panel, cables and work. The required items are listed separately in the kit statement.
Can we keep the old alarm line?
This is considered after checking the circuit, the model of the receiving device and the parameters of both connected nodes. An unknown line is not declared compatible only for its previous purpose.
Main product and related kit
CH4656 is listed first. NAVTEX is a separate equipment; it is not included in the price of the charger and is not declared a ready-made connection scheme to it.
SAILOR CH4656 - 360,000 RUB, main product
SAILOR 6390 + panel 6004 + antenna - a separate set of NAVTEX; illustration from the manual, composition according to the specificationDelivery to Russia and Kazakhstan. Indicate the city - agree on the cost and delivery time of the selected set. Current availability, condition and documents are confirmed before ordering.
Request SAILOR CH4656Replacement CH4656: what to agree on before sending
Technical data source: CH4656 / CH4666 / CH2410, sections 1.1 to 1.2. The CH4656 parameters are used; the configuration of a particular block is confirmed separately.
Charging signal to the existing panel
For a vessel on the Don to receive CH4656 in Azov, attach a panel model that should receive the signal and a current circuit circuit scheme. Other equipment can be stored in a tug with repairs in Rostov-on-Don, so a common charger order does not replace two tasks. The control signal and power supply are described separately. The quotation must show the agreed charger configuration, the necessary connections and stored devices; the place of receipt does not establish the admissibility of connecting the signal chain.